Conversion & Control

A raw temperature signal is only the starting point. It still needs to be adapted, processed, and transferred into a form the application can use. Components for conversion and control take on that task by linking field signals to automation functions. This helps you manage temperature-dependent processes more reliably, support stable control sequences, and integrate measuring points more effectively into your system architecture.
View all products

Product Overview (16)

Temperature transmitter PMT50-3

Temperature transmitter for Pt100, Pt1000 and thermocouples J, K, N and S, with programmable measuring range, 0/4..20 mA or 0/2..10 V DC output, 32-point linearization and fault detection.

Ex temperature transmitter PMT50EX-3

Ex temperature transmitter for Pt100, Pt1000 and thermocouples J, K, N and S, with intrinsically safe input, programmable range, 0/4..20 mA or 0/2..10 V DC output and 32-point linearization.

Temperature guard TG50

Temperature guard for Pt100, Pt1000 and thermocouple J, K, N and S monitoring, with up to 4 SPDT alarm outputs, optional isolated 0/4..20 mA or 0/2..10 V DC output and peak value display.

Ex temperature guard TG50EX

Ex temperature guard for intrinsically safe Pt100, Pt1000 and thermocouple J, K, N and S monitoring, with 2 SPDT alarm outputs, optional isolated analog output and peak value display.

Universal transmitter MU500

Universal transmitter for Pt100 or Pt1000 RTD signal conversion, with switch-selectable measuring ranges, 0/4..20 mA and 0/2..10 V outputs, 3-port isolation and 22.5 mm DIN rail housing.

Ex universal transmitter MU500EX

Ex universal transmitter for intrinsically safe Pt100 or Pt1000 RTD signal conversion, with switch-selectable ranges, 0/4..20 mA and 0/2..10 V outputs, 3-port isolation and 22.5 mm DIN rail housing.

Temperature transmitter MU500L

Temperature transmitter for RTD sensor signals, converting Pt100 or Pt1000 inputs into 0/4–20 mA and 0/2–10 V outputs with selectable ranges, galvanic isolation and DIN rail mounting.

Thermocouple transmitter TC500

Thermocouple transmitter for process temperature signals from Type J, K or S thermocouples, with programmable -150...1600 °C range, 0/4...20 mA or 0/2...10 V output and 3-port isolation.

Temperature measuring transmitter MU125

Temperature measuring transducer for 4..20 mA conversion of Pt100, Pt1000, thermocouple, NTC and resistance signals, with DIP-switch configuration, trim potentiometers and 12.5 mm TS35 rail housing.

Temperature measuring transducer TC125M

Temperature measuring transducer for Pt100, Pt1000 and thermocouples J, K and S, converting values to 0/4..20 mA and 0/2..10 V with 3-way isolation, trim adjustment and optional intrinsically safe inputs.

Universal transmitter UT125

Universal transmitter for converting standard signals, Pt100, thermocouples and potentiometers into 4..20 mA, with DIP-switch configuration, Pt100 fault monitoring and 12.5 mm TS35 rail housing.

Limit value switch GS125

Limit value switch for process monitoring with universal inputs for 0/2..10 V, 0/4..20 mA, Pt100, thermocouples and potentiometers, 1 or 2 relay outputs, 4..20 mA actual value output and 12.5 mm housing.

Current alarm module H2CM

Current alarm module for heating circuit supervision, monitoring 1..80 A load current in 1~ 48..530 V AC SSR temperature control circuits with 0..60 s alarm delay and DIN rail mounting.

Head temperature transmitter for HART 4...20 mA signal conversion UTN-500

Head temperature transmitter for RTD, TC, Ohm and mV inputs, with HART protocol, 2-wire 4...20 mA output, galvanic isolation, NAMUR NE43 fault reaction and head form B mounting to DIN 43729.

Temperature head transmitter for Pt100 signal conversion Transcont KTM / ExKTM

Temperature head transmitter for Pt100 signal conversion from -100°C to +600°C, with 4…20mA or 0…10V output, 2- or 3-wire Pt100 connection, 12 standard ranges and optional ExKTM ATEX version.

Temperature transmitter for Pt100 sensor signal conversion LTN-500

Temperature transmitter for Pt100 signal conversion, with 4-wire Pt100 input, 4...20 mA output, 10...30 V DC supply, M8 input and M12 output connection for integration into the measuring line.

You have seen 16/16 products