Photometric Radiometric Transmitters

Covering UVA, UVB, UVC, radiometric (RAD), photosynthetically active radiation (PAR), and photometric (PHOT) measurements, these transmitters provide continuous, accurate monitoring across the UV, visible-light, and plant-relevant spectral ranges. They convert measured light and radiation values into standardized output signals for straightforward integration into monitoring and control systems. From illuminance and UV irradiance to PAR levels, they deliver reliable data to assess lighting conditions, manage UV exposure, and monitor spectral performance in indoor, industrial, and specialized applications.
View all products

Product Overview (9)

Radiometric probe for VIS-NIR irradiance measurement LPRAD01

Radiometric probe for VIS-NIR irradiance measurement from 0…200 mW/cm2 across ≈400 nm…≈1050 nm, with mV output, individual calibration and 5 m cable for indoor monitoring.

Radiometric probe for UVA irradiance measurement LPUVA01

Radiometric probe for UVA irradiance measurement from 0…200 mW/cm², with peak response around 365 nm, mV output, individual calibration and 5 m cable for indoor monitoring.

Radiometric probe for UVB irradiance measurement LPUVB01

Radiometric probe for UVB irradiance measurement from 0…200 mW/cm2, with peak response around 305 nm, mV output, individual calibration and 5 m cable for indoor monitoring.

Radiometric probe for UVC irradiance measurement LPUVC01

Radiometric probe for UVC irradiance measurement from 0…200 mW/cm², with peak response at 260 nm, mV output, individual calibration and 5 m cable for indoor monitoring.

Transmitters for illuminance and irradiance monitoring HD2021T

Transmitters for illuminance and irradiance monitoring convert Lux and W/m2 values in V(λ), 400…1050 nm, UVA, UVB and UVC ranges into 0…10 Vdc, with IP66 protection and calibrated full-scale output.

PAR probe for indoor photosynthetic photon flux monitoring LPPAR01

PAR probe for indoor photosynthetic photon flux monitoring

Photometric probe for indoor illuminance monitoring LPPHOT01

Photometric probe for indoor illuminance monitoring, measuring 0...200 klux with V(λ) spectral response, <4% calibration accuracy, cosine corrected diffuser and passive mV output.

Illuminance transmitter for RS485 MODBUS-RTU light monitoring LPPHOT01S

Illuminance transmitter for RS485 MODBUS-RTU light monitoring, converting LPPHOT01 mV signals across 0...10,000 lux or 0...150,000 lux with IP66 wall-mount housing.

RS485 transmitter for illuminance probe integration LPPHOTS

RS485 transmitter for illuminance probe integration, converting LPPHOT mV signals to Modbus-RTU over 0…150,000 lux with 10 lux resolution, 5…30 Vdc supply and IP66 wall-mount housing.

You have seen 9/9 products