Keep runway operations, road networks, and wind farms informed with reliable visibility and present weather data from a compact forward-scatter sensor with an additional backscatter receiver. The combined measurement supports clearer separation of liquid and frozen precipitation, so present weather reporting stays dependable when conditions change.
Visibility (Meteorological Optical Range) outputs cover a standard 10 m to 20 km range, with a user-selectable maximum up to 99.99 km and 1 m or 10 m resolution. You can output MOR or extinction coefficient (EXCO) and enable WMO Table 4680 present weather codes, including precipitation type and intensity.
Integration stays flexible: serial communication (RS-232, RS-422 or RS-485) is standard, with an option board slot for ALS-2 ambient light sensor interface for RVR messaging, or for analog outputs and volt-free relays. Built-in self-test, diagnostics, and window contamination monitoring with automatic compensation help reduce maintenance effort across long deployments.
Reports instantaneous and averaged MOR and can output extinction coefficient (EXCO) and WMO Table 4680 present weather codes.
Uses forward-scattered and backscattered IR light and analyzes signal strength, duration, and ratio for visibility and precipitation discrimination.
Provides standard serial output with RS-232, RS-422, or RS-485 interfaces.
Supports no option board (serial only), ALS-2 interface for appended ambient light data, or analogues and relays interface.
Includes self-test and contamination status in every data message, plus detailed diagnostics and functional test mode.
Monitors window contamination and applies automatic compensation; transmitter window monitoring is standard.
Window heaters are fitted as standard; hood heaters are optional and can be powered separately.
Aluminium housing with powder paint finish and optional hard anodize base layer, rated IP66/IP67.
Code: 20 [1] [2] [3] [4] [5] [6] [7] [8]
Example: 20A.HV.J.A.PG.NA.UK.RC
[1] Housing
Blank = Powder coated aluminium (standard)
A. = Hard coat anodized, powder coated
[2] Hood Heating
NH. = Without heating
HV. = With heating
[3] Standard outputs
J. = Standard outputs (RS-232 / RS-422 / RS-485)
[4] Self-Test and Monitoring
S. = Standard self-test and monitoring
A. = Advanced self-test and monitoring
[5] Cable glands
PG. = Standard plastic cable glands
MG. = Single metal cable gland
[6] Option board
NA. = Without Option Board
WA. = With ALS-2 Interface
AR. = With analogues and relays interface
[7] Precipitation Definitions
xx
[8] Configuration
RC = Regular configuration
SC = Special configuration