Ultra-compact temperature sensor for fast process temperature measurement

Thermocont TK4SS

Ultra-compact temperature sensor for process temperature measurement from -50°C...+200°C, with Pt100 or Pt1000 class A sensor, 4...20 mA/FSK, RS485 Modbus-RTU or IO-Link outputs and ingress protection (IP69K/IP67).

Introduction

Tight installation spaces and fast process changes need a sensor that reacts quickly without adding complexity. This ultra-compact temperature sensor measures gases, vapors, liquids and dusts from -50°C...+200°C and is designed for time-critical applications with restricted mounting conditions.
 
The thin-film Pt-platinum sensor is in direct contact with the probe tube, supporting ideal heat transfer and response times down to t50 \leq 1s and t90 \leq 2s. Pt100 and Pt1000 class A versions follow IEC 60751, while transmitter variants offer 4...20 mA with FSK interface, RS485 Modbus-RTU or IO-Link for integration into modern control systems.
 
A completely welded measuring system seals the sensor against the process. Stainless steel construction, M12 connection and ingress protection (IP69K/IP67) support robust installation, while threaded, clamp, milk pipe and Varivent process connections cover standard and hygienic applications.

Fast response
Fast response
Direct sensor contact supports t50 ≤ 1s and t90 ≤ 2s.
Compact fit
Compact fit
M12 connection and small stainless steel design suit restricted installations.
Output choice
Output choice
Select Pt100, Pt1000, 4...20 mA/FSK, RS485 Modbus-RTU or IO-Link.
Process sealed
Process sealed
Completely welded measuring system is sealed against the process
High protection
High protection
Ingress protection (IP69K/IP67) supports demanding industrial use.
Hygienic options
Hygienic options
Metallic sealing allows dead-space and elastomer-free process adaption.

Features

Pt-platinum sensor

The device uses a Pt-platinum resistance sensor according to IEC 60751, available as Pt100 or Pt1000 class A in 4-wire configuration.

Electronic outputs

Output versions include direct resistance signal, current 4...20 mA with FSK interface, RS485 Modbus-RTU and IO-Link with current or switching outputs.

Process connections

Connection options include G¼"A, G½"A, NPT ¼", NPT ½", front-flush G½"A, milk pipe coupling DIN 11851, clamp DIN 32676 and Varivent F.

Measuring ranges

Configurable temperature ranges include 0°C...+50°C, 0°C...+200°C, -50°C...+50°C and -50°C...+200°C, depending on variant.

Neck tube

The sensor can be configured without neck tube or with a 35 mm neck tube for higher process temperatures.

Process materials

 Process-wetted materials include steel 1.4571/316Ti, with FKM/FPM – FDA or EPDM – FDA process seal options.

M12 electrical connection