Radar filling level sensor for liquids, tanks up to 10 m

Radarcont RP4SR

Radar filling level sensor for liquids in tanks up to 10 m. Measures level, volume and distance with 122...123 GHz FMCW radar, IO-Link® or RS485 Modbus-RTU, 0/4…20mA output and ingress protection (IP65/IP67).

Introduction

Reliable level data starts with a sensor that can work where optical or ultrasonic principles reach their limits. Radarcont® RP4SR measures liquid levels, volume and distance without contact, making it well suited for tanks, open channels, measuring weirs, water and waste water applications, environmental technology and process industry use.
 
The 122...123 GHz pulsed FMCW radar signal supports continuous measurement up to 10 m and uses a narrow 10° beam angle to reduce interference from internal structures or foreign objects. It can measure liquids even with gas stratification, such as ammonia, or foaming, and can also measure through container walls such as IPC containers or through PTFE or PP protection windows, depending on the application.
 
For integration into automation and monitoring systems, the sensor offers IO-Link® V1.1 with 0/4…20 mA and switching outputs, or RS485 Modbus-RTU. Characteristic deviation is ≤±0.1% FSI, with ingress protection (IP65/IP67), -20 °C …+70 °C process temperature range, temperature compensation and integrated overvoltage protection.

Non-contact control
Non-contact control
Measures liquid level, volume and distance without contact using 122...123 GHz FMCW radar
Tank-ready range
Tank-ready range
Covers tanks up to 10m with a narrow 10° beam angle to reduce internal interference
Process confidence
Process confidence
Characteristic deviation ≤± 0.1% FSI supports reliable continuous measurement
System integration
System integration
IO-Link® V1.1, RS485 Modbus-RTU and 0/4…20mA outputs support automation use
Protected housing
Protected housing
Ingress protection (IP65/IP67) and integrated overvoltage protection support field use
Difficult media fit
Difficult media fit
Measures liquids with gas stratification or foaming, depending on the application

Features

FMCW radar measurement

The sensor emits a pulsed FMCW radar signal and calculates distance from the reflected signal delay and frequency difference.

Level and volume values

The measured distance to the liquid surface can be converted into level or volume values and linearized where required.

Output variants

The product is available with RS485 Modbus-RTU or with IO-Link®, current 0/4…20 mA and push-pull switching outputs.

Temperature function

The electronics function can include temperature measurement for -20 °C …+70 °C applications.

Process connection

The sensor uses a DIN 13 M30x1.5 thread process connection for installation in the application.

Material construction

Non-process-contacting materials are PE-HD, POM, PA and FPM.

Electrical connection

Cable versions include PE cable without confection, confectioned wires or Hydrolog HLF4 confection.

Configuration

Operation and parameterization can be carried out via the SmartConnect App or the wired interface.