Thermocouple thermometer for dual-channel field measurement

PRO 13x.2

Thermocouple thermometer for dual-channel temperature checks with K, J, T, N, R, S, B and E probes, -220.0...+1750 °C coverage, differential display, Min/Avg/Max statistics and IP 67 housing. Optional data logging (PRO 135.2).

Introduction

Precise temperature checks in the field need clear readings, flexible probe choice and a housing that copes with daily handling. This handheld family measures two thermocouple channels at once and automatically shows the temperature difference, making it suitable for comparing two measuring locations with one instrument.
 
Standard K, J, T, N, R, S, B and E thermocouple probes can be connected, covering ranges from -220.0...+1750 °C depending on type. The instruments support °C, °F and K, detect Min/Avg/Max values, and offer Hold and Rel functions for controlled field work. PRO 135.2 adds data logging with up to 1 million data sets, stored as CSV files with date and time stamp for USB readout.
 
A backlit 140 x 160 dot matrix display keeps values readable from daylight to darkness, with large-value, multi-row, statistics and chart views. The IP 67 housing, except probe connection, IK 06 impact rating, foldable stand and magnet support practical use on site.

Two-point checks
Measure two thermocouple channels and view the temperature difference directly on the display.
Wide probe choice
Connect K, J, T, N, R, S, B and E thermocouple probes for applications up to +1750 °C.
Clear field reading
Backlit 140 x 160 dot matrix LCD shows large values, statistics or a live chart view.
Built for site use
IP 67 housing (except probe connection) and IK 06 protection support demanding field work.
Logged records
PRO 135.2 stores up to 1 million data sets as CSV files with date and time stamp.

Features

Thermocouple inputs

Two miniature female flat-pin TC connectors accept standard thermocouple probes for the supported probe types.

Measurement display modes

The display can show large single values, multiple rows, statistical information or one parameter as a numerical and graphical view.

Statistical functions

Minimum, average and maximum values can be detected for each channel, with reset control for a new calculation.

Alarm configuration

High and low alarm thresholds can be set with optional hysteresis, using LCD indication and buzzer activation when limits are exceeded.

Measurement adjustment

Zero point, gradient and surface correction settings allow the displayed value to be adjusted for each input channel.

Power supply

The instruments operate from 4 AA alkaline batteries or external 5 Vdc via USB C; auto-off and backlight settings are configurable.

PC connection

USB C supports connection to a PC for serial communication and data acquisition in COM interface mode.

Data logging

PRO 135.2 records measurements automatically with configurable intervals and stores the data in the internal memory.