Indoor air checks become clearer when the key comfort and safety-related parameters are captured at the same time. This portable IAQ monitor measures CO2, CO, atmospheric pressure, temperature and relative humidity simultaneously, then calculates dew point, wet bulb temperature, absolute humidity, mixing ratio and enthalpy for a fuller view of indoor conditions.
It supports practical work in schools, offices, factories, indoor spaces, HVAC checks and building automation. The backlit 160 x 160 dot matrix display gives direct readings on site, while the 67600-recording data logger stores measurement sessions in 64 blocks for later analysis on a PC.
Factory-calibrated sensors reduce preparation before use. CO2 measurement covers 0...5000 ppm with NDIR Dual Wavelength technology, CO measurement covers 0...500 ppm with an electrochemical cell, and the instrument is referenced to ASHRAE 62.1 for confined spaces used by people.
The instrument calculates dew point, wet bulb temperature, absolute humidity, mixing ratio and enthalpy from the measured indoor air parameters.
A backlit Dot Matrix graphic LCD shows the selected main quantity in larger characters and lists the other detected values on the same screen.
The FUNC key displays maximum, minimum, average and 1-minute average values for the captured quantities during normal operation.
Logging sessions can be started manually with the MEM key or programmed with defined start and end dates and times.
Logged data can be transferred to a PC through the mini-USB serial port at a fixed transfer speed of 460800 bps.
The menu supports calibration of CO2, CO and relative humidity sensors, with factory calibration restore available for CO2.
| Sensor type temperature |
NTC
|
|---|---|
| Temperature range |
-20...+60 °C
|
| Accuracy temperature |
±0.15 % OR ±0.2 °C
|
| Sensor type pressure |
Piezoresistive
|
| Pressure range |
750...1100 hPa
|
| Resolution pressure |
1 hPa
|
| Accuracy pressure |
±1.5 hPa @ 25 °C
|
| Sensor type relative humidity |
Capacitive
|
| CO₂ principle |
NDIR Dual Wavelength
|
| Relative humidity range |
0...100 %RH
|
| Resolution temperature |
0.1 °C
|
| Resolution relative humidity |
0.1 %RH
|
| Accuracy relative humidity |
±2% (10÷90 %RH) ±2.5% in the remaining range
|
| CO₂ accuracy |
±50 ppm+3% of measure
|
| Long-term drift temperature |
±0.1 °C/year
|
| Long-term drift relative humidity |
±1 %RH/year
|
| Long-term drift pressure |
±2 hPa/year
|
| Operating temperature |
-5...+50 °C
|
|---|---|
| Condensation |
not permitted
|
| Storage temperature |
-25...+65 °C
|
| Operating relative humidity |
0...85 %RH
|
| Materials |
ABS, Rubber
|
|---|---|
| Weight |
470 g
|
| Dimensions |
90 mm x 40 mm x 300 mm
|
| Interval |
selectable among 15, 30 s; 1, 2, 5, 10, 15, 20, 30, min and 1 hour
|
|---|---|
| Capacity |
67600
|
| Interface type |
USB
|
|---|---|
| Baud rate |
460800
|
| Current consumption |
< 45 µA
|
|---|---|
| Battery type |
Rechargable battery 4x AA NiMH
|
| Battery life |
8 h
|
| Auxiliary voltage |
12 V DC
|
| Display type |
LCD backlit
|
|---|---|
| Description |
Backlit, Dot Matrix 160 x 160 dots, visible area 52 x 42 mm
|
| Accuracy indication |
±1 Digit @ 20 °C
|