GTF102P is a srew-in resistance temperature sensor in a 3mm (other diameters available) stainless steel tube with fixed cable.
It is available as Pt100 or Pt1000 (1/10B, AA, A or B class), thinfilm or wire-wound in custom length.
Three temperature ranges (250/400/600°C) are avaiale to allow best adaption to process requirements beween maximum temperature and repsonse times.
Cable can be configured silicon, pvc, ptfe or glass fibre insulated. The cable is protected by an extention tube and supported by a coil spring in the standard version (also avaivable without extention tube and coil spring).
Available for following max. proecess temperatures at sensors tip:
LT: -200...250°C (fast response in lower temperature)
MT: -200...+400°C (fast response in medium temperatures)
HT: -200...+600°C (mineral isulated; good response in higher termperatures)
Note: The maximum operating temperature of the cable must not be exceeded on either the cable sleeve or the cable itself!
Available RTD elements acc. to IEC751/EN60751:
Note: Wire wound sensor and 1/10 class B elements are available vor Pt100, only.
Other:
Available in 3/4/5 or 6mm dianmeter in lenght up to 1000mm in 5mm minmum steppings.
G1/2" (standard) or G1/4"
Type (allowed temperatures)
| Media temperature |
-200...+600 °C
|
|---|
| Temperature sensor |
Pt100, Pt1000, Class 1/10B, AA, A, B
For Pt100: Pt100 For Pt1000: Pt1000 For B class DIN EN 60751 (-50…+500°C, thin-film): B For A class DIN EN 60751 (-30…+300°C, thin film): A For A class DIN EN 60751 (-100…+450°C, wire-wound): A For AA class DIN EN 60751 (0…+150°C, thin film): AA For 1/10B class (-50…+100°C, wire-wound): 1/10B |
|---|---|
| Measuring principle |
RTD
|
| Electrical connection type |
loose ends
For Loose ends with wire end ferrules: loose ends |
|---|
| Cable |
PVC, PTFE, Silicon, Flexible fiberglass with steel wire braiding
For 2-wire: 2-wire For 3-wire: 3-wire For 4-wire: 4-wire For 1 m PVC cable, -20 ... +105 °C: 1 m PVC For each additional meter (PVC cable): PVC For 1 m silicone cable, -50 ... +200 °C: 1 m Silicon For each additional meter (silicone cable): Silicon For 1 m Teflon cable, -200 ... +250 °C: 1 m PTFE For each additional meter (silicone cable): Silicon For 1 m glass fibre, -50 ... +400 °C: 1 m Flexible fiberglass with steel wire braiding For each additional meter (glass fibre insulated cable): Flexible fiberglass with steel wire braiding For each additional meter (teflon cable): PTFE |
|---|---|
| Probe Diameter |
For 3 mm: 3 mm
For 4 mm: 4 mm For 5 mm: 5 mm For 6 mm: 6 mm |
| Probe length |
For 50 mm: 50 mm
For 100 mm: 100 mm For 150 mm: 150 mm For 250 mm: 250 mm For 500 mm: 500 mm |