Screw in resistance temperature probe

GTF102P

GTF102P is screw-in resistance temperature sensor in a 3mm stainless steel tube with fixed cable. It is available as Pt100 or Pt1000 (1/10B, AA, A or B class), thinfilm or wire-wound in custom length.

Introduction

GTF102P is a srew-in resistance temperature sensor in a 3mm (other diameters available) stainless steel tube with fixed cable.
It is available as Pt100 or Pt1000 (1/10B, AA, A or B class), thinfilm or wire-wound in custom length.

Three temperature ranges  (250/400/600°C) are avaiale to allow best adaption to process requirements beween maximum temperature and repsonse times.

Cable can be configured silicon, pvc, ptfe or glass fibre insulated. The cable is protected by an extention tube and supported by a coil spring in the standard version (also avaivable without extention tube and coil spring). 

 

 

High flexibility
High flexibility
Pt100 and Pt1000 elements avainalbe in class AA, A, B or 1/10B as thin-film or wire-wound sensor.
Robust design
Robust design
3/4/5 or mm protective tube in custom length with process thread.
Faster response time
Faster response time
LT or MT version in 3mm vor fast response times.

Features

Constructive design

Available for following max. proecess temperatures at sensors tip:

LT: -200...250°C (fast response in lower temperature)

MT: -200...+400°C (fast response in medium temperatures)

HT: -200...+600°C (mineral isulated; good response in higher termperatures)

Note: The maximum operating temperature of the cable must not be exceeded on either the cable sleeve or the cable itself!

Sensor element

Available RTD elements acc. to IEC751/EN60751:

Note: Wire wound sensor and 1/10 class B elements are available vor Pt100, only.

  • B            -196...+600°C or -50...+500°C
  • A            -100...+450°C or -30...+300°C
  • AA(1/3B) - 50...+250°C  or 0...+150°C

Other:

  • 1/10B      -50...+100°C
Protective tube

Available in 3/4/5 or 6mm dianmeter in lenght up to 1000mm in 5mm minmum steppings.

Process threads

G1/2" (standard) or G1/4"

Available cable insulation

Type (allowed temperatures)

  • PVC (-20...+105°C)
  • Silicon (-50...+200°C)
  • Teflon (-200...+250°C)