SICRAM module for pyranometer and albedometer mV signals

VP472

SICRAM module for pyranometer and albedometer mV signals, measuring -25...+25 mV and converting sensor output to W/m2 values with adjustable sensitivity from 5000 to 30000 nV/(Wm-2).

Introduction

Radiometric measurements become easier to record and evaluate when mV-output pyranometers and albedometers can be connected directly to the HD31 instrument. This SICRAM module reads thermopile signals in the -25...+25 mV range and supports the display of global radiation in W/m2.
 
For albedometer measurements, the instrument can show incident and reflected thermopile signals, incident and reflected global radiation, net radiation and albedo. That gives users a clearer view of radiation balance from one connected module, without reducing the measurement to raw voltage values only.
 
Setup is kept practical on site. The sensor sensitivity is entered in the instrument in nV/(Wm-2), within a range from 5000 to 30000 nV/(Wm-2), with 10000 nV/(Wm-2) as the default value. A 6-pole terminal block with screw connectors supports correct wiring of the pyranometer or albedometer signals.

Ready for W/m2
Ready for W/m2
Converts thermopile mV output into global radiation values in W/m2.
Albedo insight
Albedo insight
Displays incident and reflected radiation plus albedo with an albedometer.
mV signal range
mV signal range
Measures pyranometer and albedometer outputs from -25...+25 mV.
Flexible sensitivity
Flexible sensitivity
Set sensor sensitivity from 5000 to 30000 nV/(Wm-2).

Features

Pyranometer connection

The module connects pyranometers with mV output and allows the instrument to display the thermopile signal and global radiation.

Albedometer connection

With an albedometer, the instrument displays incident and reflected thermopile signals, radiation values, net radiation and albedo.

Sensitivity setting

The instrument stores the sensor sensitivity used to calculate global radiation from the output voltage signal.

Screw terminal wiring

A 6-pole terminal block with screw connectors is used for wiring the pyranometer or albedometer with correct signal polarity.