3-axis ultrasonic anemometer with integrated meteo sensors

HD2003

Ultrasonic anemometer measuring wind speeds from 0 to 70 m/s and wind direction from 0 to 360° azimuth with ±60° elevation, equipped with a compass, temperature, humidity and pressure sensors, RS232/RS485 Modbus-RTU interfaces, five analog outputs and optional heating.

Introduction

High-quality wind data becomes much easier to manage when one instrument covers the core anemometric quantities and the supporting environmental context. HD2003 is a 3-axis ultrasonic anemometer that measures wind speed and direction, U-V-W Cartesian components, wind gust, sound speed and sonic temperature, and also measures air temperature, relative humidity and barometric pressure.
 
Designed for continuous outdoor operation, the ultrasonic principle avoids moving parts and maintains accuracy across changing conditions. Wind speed and direction are derived from the transit time of ultrasonic pulses, a method that cancels dependence on pressure, temperature and humidity. A built-in compass with magnetic azimuth supports automatic alignment to magnetic North, while moving averages can be set from 1...60 s or 1...60 min to match your logging and control strategy.

 Integration flexibility is a core strength. The instrument offers five digital communication interfaces (RS232, RS422 on request, RS485 Modbus-RTU, RS485 Multidrop and AoXnd) and up to 5 analog outputs in current or voltage, with an option for up to 12 extended analog outputs via external modules. For cold-weather sites, HD2003R adds integrated heating of the sonic transducers to prevent ice and snow formation.

3-axis wind vector
Measures U-V-W components plus azimuth (0...360°) and elevation (±60°).
Built-in meteo context
Adds Pt100 air temperature, 5...98 %RH humidity and 600...1100 mbar pressure.
Flexible outputs
RS232/RS485 Modbus-RTU plus up to 5 analog outputs and up to 12 extended outputs.
Cold-weather option
HD2003R heating helps prevent ice buildup on sonic transducers.

Features

Anemometric quantities

Measures wind speed, wind direction, U-V-W components, wind gust, sound speed and sonic temperature.

Wind performance

Wind speed range is 0...70 m/s with 0.01 m/s resolution and ±1% of reading accuracy.

Wind direction geometry

Wind direction includes azimuth 0...360° and elevation ±60°, with 0.1° resolution and ±1° accuracy.

Analog output capability

5 analog outputs are configurable as 0...20 mA, 4...20 mA, 0...1 V, 0...5 V, 0...10 V or 1...5 V at up to 14-bit resolution.

Digital communication

Supports RS232, RS485 Modbus-RTU, RS485 Multidrop and AoXnd, with RS422 full-duplex available on request.

Averaging and high-frequency modes

Output rate can be set from 1...3600 s in normal mode, with a fixed 50 Hz digital high-frequency mode available.