Clean water applications need stable conductivity measurement without unnecessary complexity. GLMU 200 MP measures conductivity and calculated values in liquids, using a cost-optimized 2-pole measuring cell for pure water, drinking water and freshwater tasks.
The transmitter helps operators adapt one device to several measurement needs. It can be configured for conductivity, specific resistivity, TDS or salinity and temperature shown on the 4-digit LCD display.
Integration into control or monitoring systems is straightforward. The measured value is supplied via a scalable 4...20 mA output or optional 0...10 V output, while temperature compensation can be set to none, nonlinear compensation for natural waters according to EN 27888, or linear compensation with an adjustable coefficient.
The device can be set for conductivity, specific resistivity, TDS or salinity. The selected function determines the available ranges and display unit.
Configurable ranges
GLMU200MP-TR(P)
Conductivity (Resistivity; TDS)
GLMU200MP-RW(P)
Conductivity (Resistivity; TDS)
LMU 200 MP uses a 2-pole measuring cell and is intended for pure water, drinking water and freshwater.
Compensation can be switched off, set to nonlinear compensation for natural waters according to EN 27888, or set to linear compensation with an adjustable coefficient
The output is available as 4–20 mA in two-wire connection or as 0–1 V / 0–10 V in three-wire connection. The version is fixed at the factory.
The lower and upper output points are configured by entering the display values assigned to 4 mA or 20 mA, or to the voltage output limits.
The device shows the current measured value during operation. A key press switches briefly to temperature display, and minimum and maximum values can be viewed and cleared.
Parameters are set directly by keyboard, including cell constant, measuring function, measuring range, temperature reference, TDS factor and temperature correction.
| Conductivity range, max |
0...200 mS/cm
|
|---|---|
| Conductivity range, min |
0...20 µS/cm
|
| Temperature compensation |
non linear function, linear function (coefficient configurable) or none
|
| Accuracy Conductivity |
0.3 % FS
|
| Temperature range |
-5...+140 °C
|
| Accuracy temperature |
±0.1 % OR
|
| Cell constant |
For LFE-202 for drinking/fresh water: 1 1/cm
For LFE-230 for drink/fresh water, screw-in measuring cell: 0.9 1/cm For LFE-240 for ultrapure water: 0.1 1/cm For LFE-220 for ultrapure water, screw-in measuring cell: 0.1 1/cm |
| Operating relative humidity |
< 95 %RH
|
|---|---|
| Degree of protection front |
IP65
|
| Operating temperature |
-25...+50 °C
|
| Storage temperature |
-25...+70 °C
|
| Dimensions |
82 mm x 80 mm x 55 mm
|
|---|---|
| Materials |
ABS
|
| Mounting |
Field
|
| CE Conformity |
Yes
|
|---|
| Electrical connection type |
Elbow-type plug
For LFE-202 for drinking/fresh water: Fixed cable connection For LFE-230 for drink/fresh water, screw-in measuring cell: M12 8-pole circular connector For LFE-240 for ultrapure water: Fixed cable connection For LFE-220 for ultrapure water, screw-in measuring cell: M12 8-pole circular connector |
|---|
| Accuracy indication |
4-digit
|
|---|---|
| Display type |
LCD
|
| Type of controls |
3 Button
|
| Media temperature |
For LFE-202 for drinking/fresh water: -5...+80 °C
For LFE-230 for drink/fresh water, screw-in measuring cell: 0...60 °C For LFE-240 for ultrapure water: -5...+80 °C For LFE-220 for ultrapure water, screw-in measuring cell: -10...+100 °C |
|---|
| Auxiliary voltage, analog output (passive) |
For 4 ... 20 mA: 12...30 V
For 0 ... 10 V: 18...30 V |
|---|---|
| Burden, external |
For 4 ... 20 mA: RA(Ohm) < ( (Uv – 12 V) / 0.02 A )
For 0 ... 10 V: > 3000 Ohm |
| Type of analog output (passive) |
For 4 ... 20 mA: 4…20 mA 2-Wire
For 0 ... 10 V: 0…10 V 3-Wire |
| Cable |
For 1 m: 1 m
For 2 m: 2 m For 3 m: 3 m For 4 m: 4 m For 5 m: 5 m For 6 m: 6 m For 2 m: 2 m For 5 m: 5 m For 6 m: 6 m |
|---|
| Process connection |
For LFE-202 for drinking/fresh water: Without, PG13.5
For LFE-230 for drink/fresh water, screw-in measuring cell: G ½" For LFE-240 for ultrapure water: Without For LFE-220 for ultrapure water, screw-in measuring cell: G ½" |
|---|