Rotary paddle level switch for bulk solid silo monitoring

Silocont SIC-350

Rotary paddle level switch for bulk solid limit detection in silos, for full, empty and demand indication, with ≥ 80 g/l minimum density, 0.5 to 2.5 bar abs. and AC/DC supply options.

Introduction

Bulk solid silos need a limit switch that is simple to install, easy to check and robust enough for dusty operating conditions. Silocont SIC-350 detects full, empty and demand levels in bulk solids using a mechanical rotary paddle principle.
 
The compact polymer housing and straightforward mechanism support economical level monitoring across the device lifecycle. Optical rotation control helps installers and service teams check operation quickly without dismantling the unit, while optional automatic rotation monitoring adds security for overfill protection.
 
The sensor covers process temperatures from -20 °C to +80 °C and absolute process pressure from 0.5 to 2.5 bar. Supply options include 230 VAC, 115 VAC, 24 VAC and 20 to 28 VDC, with a microswitch changeover contact output. Versions are available with shaft lengths from 75 mm to 300 mm or a shorten-able rope length of approx. 2000 mm.

Simple silo control
Simple silo control
Detects full, empty and demand levels in bulk solid silos
Fast rotation check
Fast rotation check
Optical rotation control supports quick installation and troubleshooting
Flexible mounting
Flexible mounting
Housing rotates up to 360° for alignment after installation
Length options
Length options
Shaft lengths up to 300 mm or shorten-able rope version approx. 2000 mm

Features

Rotary paddle principle

The device uses a mechanical rotary paddle measuring principle for limit detection in bulk solids.

Bulk solid applications

It is used as a full, empty or demand indicator in silos and is specified for media densities ≥ 80 g/l.

Supply variants

Available supply versions include 230 VAC 50/60 Hz, 115 VAC 50/60 Hz, 24 VAC 50/60 Hz and 20 to 28 VDC.

Output contact

The switching output is a microswitch with changeover contact, specified up to max. 6 A/250 VAC 100 mA.

Process connections

Connection options include NPT 1-½", NPT 1-¼" and G 1-½" threads, with PBT or 303 material versions.

Measuring paddle options

The measuring paddle is available as standard or foldable version, with 304 material stated in the order code.

Optional accessories

Options include rotation control system, signal lamp, foldable measuring paddle and weather protection cover.