Piston inline flow transmitter

OMNIPLUS-HD2

Flow transmitter for viscous media measurement, covering 0.5 ... 60 l/min for oils and media from 30 ... 330 mm²/s. It combines configurable outputs, IO-Link and an IP65/IP67 housing.

Introduction

Viscous media place different demands on flow measurement, especially where pressure, installation space and changing operating conditions matter. This transmitter family is designed for oils and other viscous media from 30 ... 330 mm²/s, with viscosity-stabilized measurement and ranges from 0.5 ... 60 l/min.
 
The spring-supported variable area principle gives the measurement a robust mechanical basis. A magnet-equipped float moves against a spring, while magnetic field sensors detect its position outside the flow chamber. DN 8 ... DN 25 sizes, female threads from G 1/4 to G 1 and no required inlet or outlet runs make the family practical for compact industrial installations.
 
Integration is straightforward through one configurable analog output, two switching outputs and IO-Link V1.1. PN 200 pressure resistance, optional PN 500, IP65/IP67 protection and brass or stainless steel versions support reliable use in demanding industrial systems.

Viscous media fit
Viscous media fit
Viscosity-stabilized design measures oils and viscous media from 30 ... 330 mm²/s.
High pressure use
High pressure use
PN 200 pressure resistance supports demanding circuits; PN 500 is available on request.
No straight runs
No straight runs
No inlet or outlet runs are required, reducing installation effort in compact systems.
Flexible outputs
Flexible outputs
Analog output, two switching outputs and IO-Link V1.1 support control systems.
Clear alarm display
Clear alarm display
The 1.2 inch LCD uses white backlighting and red backlighting for alarm messages.

Features

Spring-supported measuring principle

The transmitter uses a spring-supported variable area principle. A magnet-equipped float is moved by the medium, and magnetic field sensors detect its position outside the flow chamber.

Nominal sizes and ranges

The product family covers DN 8 ... DN 25 and measuring ranges from 0.5 ... 8 l/min up to 12.0 ... 60 l/min for viscous media.

Mechanical connection

The devices use female threads from G 1/4 to G 1. Further connection types are available on request according to the source.

Analog output

The analog output can be configured for current or voltage, including 4 ... 20 mA, 0 ... 20 mA, 0 ... 10 V, 2 ... 10 V, 0 ... 5 V, 1 ... 5 V and 0.5 ... 4.5 V.

Switching outputs

Two push-pull transistor outputs can be set as limit switches, frequency outputs, pulse outputs or outputs for the preset counter.

IO-Link communication

The device supports IO-Link V1.1 with COM2 transmission, SIO mode, block parameterization and data storage.

Display and alarm indication

The graphical 1.2 inch LCD has 128 x 64 pixels and uses white backlighting in normal operation and red backlighting for alarm messages.

Material and options

The family is available in brass and stainless steel versions, with an optional extended temperature range to +150 °C using distance pieces.