Double input RTD thermometer for temperature comparison

HD2127.1

No data logger, Double input RTD thermometer for Pt100, Pt1000 and Ni1000 probes, measuring -200...+650°C or -50...+250°C by sensor type, with 0.01°C resolution, A-B function, IP66 protection and optional logging.
Order Code:
HD2127.1
Article Number:
VHD2127.1

Introduction

Comparing two temperature points in the same process should not mean switching probes or instruments. The HD2127 family measures two channels at once and calculates the A-B temperature difference, making it well suited for checks with immersion, penetration, contact or air probes.

The instruments support Pt100 probes with SICRAM module, direct 4-wire Pt100 sensors, 2-wire Pt1000 and 2-wire Ni1000 probes. SICRAM modules store factory calibration data and are detected automatically at start-up, while the instrument provides 0.01°C resolution within ±199.99°C and instrument accuracy of ±0.01°C, excluding probe error.

For field documentation, both models offer a large LCD, MAX, MIN, AVG, REL and HOLD functions, RS232C transfer and IP66 protection. The HD2127.2 adds USB 2.0 and internal logging for up to 32,000 samples across channels A and B, with selectable intervals from 1s to 1hour.

Two-channel checks
Measures inputs A and B and calculates the A-B temperature difference.
High accuracy
Instrument accuracy is ±0.01°C, excluding probe error, with 0.1°C/year drift.
Probe recognition
SICRAM Pt100 probes store factory calibration data for automatic detection.
Protected field use
IP66 housing with ABS and rubber construction supports portable work.
Logging option
HD2127.2 stores 32,000 samples with intervals from 1s to 1hour.
PC transfer
RS232C is standard; HD2127.2 also adds USB 2.0 with Mini-USB connector.

Features

Dual RTD inputs

Two 8-pole DIN45326 connectors accept temperature probes on channels A and B for parallel measurement.

Supported sensors

The inputs work with Pt100 probes with SICRAM module, direct 4-wire Pt100, 2-wire Pt1000 and 2-wire Ni1000 probes.

Measurement display

The main display line shows channel A, while the secondary display line shows channel B or the A-B difference.

User calibration

Factory calibration is available as standard, and user calibration can be carried out for each channel on one or two points.

Data logging

HD2127.2 records measurement pairs in internal memory and retains stored data independently of battery charge conditions.

Communication ports

The instruments provide electrically isolated RS232C; HD2127.2 also includes electrically isolated USB 2.0.

Power supply

The family operates with 4 x 1.5V AA batteries for 200 hours autonomy or with a 12Vdc mains adapter.